FRONT PANEL CALIBRATION POINTS (continued)
VU ADJ
VU ADJUST is for calibration of VU only. It does not affect GAIN REDUCTION readings.
VU ADJ - CALIBRATION PROCEDURE:
•
Set PEAK REDUCTION & LIMITER RESPONSE fully-counterclockwise.
•
Set OUTPUT LEVEL, LIMITER FEEDBACK & STEREO LEVEL RIDE to UNITY.
•
Set IN/BYPASS to BYPASS
•
Allow 10 minutes system warm-up time and 1 minute rest from any peak reduction activity.
•
Inject a +10dBu (2.45V) 1-kHz tone (both channels). Verify level using an external DMM or
suitable meter. If your DMM has a dB function, select that. If not, set to A/C and read
2.45VAC across pins 2&3 of the OUTPUT XLR.
•
Set IN/BYPASS to IN
•
Select +10 on the METER SELECT and observe if the VU METER reads 0dB.
•
Adjust as necessary.
•
+4dBu is factory set to follow the +10dBu calibration. After the above calibration is com-
pleted, the VU METER should read 0dBu when METER SELECT is set to +4 and a 1-kHz tone
of .775v is applied to the input.
STEREO ADJ
STEREO ADJUST (2 each) - In order to achieve proper stereo or multi-channel gain re-
duction action, each channel should be adjusted to be equal. Carefully read the STE-
REO ADJUST calibration procedure to be sure you have a thorough understanding be-
fore attempting calibration. The L2M is fully calibrated for stereo operation before leav-
ing our shop.